Choose another country or region to see content specific to your location and shop online.
Free Shipping Over $100*

3M Attest 1492V Super Rapid Readout Biological Indicator 50/Box

0 answered questions
SKU: VM3M-1492V
Mfr. P/N: 3M-1492V
Twenty-four minute readout Biological Indicator for 132°C (270°F) 3 or 4 minute and 135°C (275°F) 3 minute Dynamic-Air-Removal Steam Sterilization cycles. Brown cap. 50 each/box. The 3M Attest Super Rapid Readout Biological Indicator 1492V is a self‑contained biological indicator specifically designed for rapid and reliable qualification testing and routine monitoring of 270°F (132°C) and 275°F (135°C) dynamic‑air‑removal (pre‑vacuum and steam-flush pressure-pulse (SFPP)) steam sterilization processes when used in conjunction with the 3M Attest Auto‑reader 490 or the 3M Attest Auto-reader 490H having software version 4.2.7 or greater. The self‑contained design includes a carrier with spores of Geobacillus stearothermophilus and a media ampoule containing bacteriological media. The spore carrier and media ampoule are contained in a plastic vial topped with a brown cap. A chemical process indicator which changes from pink to light brown or darker upon exposure to steam is located on the top of the cap. After processing, the biological indicator is activated and incubated in the 3M Attest Auto-reader. A final negative reading after the specified incubation period indicates an acceptable sterilization process. A 24-minute result is provided when incubated in Model 490 or 490H Auto-readers having software version 4.2.7 or greater. - Provides BI results in 24 minutes in 3M Attest 490/490H Auto-readers with software version 4.2.7 or greater - Dynamic-air-removal (Pre-vacuum and SFPP): 132˚C (270˚F) 3 or 4 min. 135˚C (275˚F) 3 min. - Meets ISO and FDA performance requirements for biological indicators - Contains viable organisms that provide a direct measure of lethality - Puts your instrument turnaround speed into overdrive - Puts your instrument turnaround speed into overdrive for improved patient safety *When used with 3M™ Attest™ Auto-reader 490 or the Attest™ Auto-reader 490H with software version 4.2.7 or greater.

Availability: In Stock

This product ships within 3 - 4 Weeks (Special Order)

Details

Twenty-four minute readout Biological Indicator for 132°C (270°F) 3 or 4 minute and 135°C (275°F) 3 minute Dynamic-Air-Removal Steam Sterilization cycles. Brown cap. 50 each/box. The 3M Attest Super Rapid Readout Biological Indicator 1492V is a self‑contained biological indicator specifically designed for rapid and reliable qualification testing and routine monitoring of 270°F (132°C) and 275°F (135°C) dynamic‑air‑removal (pre‑vacuum and steam-flush pressure-pulse (SFPP)) steam sterilization processes when used in conjunction with the 3M Attest Auto‑reader 490 or the 3M Attest Auto-reader 490H having software version 4.2.7 or greater. The self‑contained design includes a carrier with spores of Geobacillus stearothermophilus and a media ampoule containing bacteriological media. The spore carrier and media ampoule are contained in a plastic vial topped with a brown cap. A chemical process indicator which changes from pink to light brown or darker upon exposure to steam is located on the top of the cap. After processing, the biological indicator is activated and incubated in the 3M Attest Auto-reader. A final negative reading after the specified incubation period indicates an acceptable sterilization process. A 24-minute result is provided when incubated in Model 490 or 490H Auto-readers having software version 4.2.7 or greater. - Provides BI results in 24 minutes in 3M Attest 490/490H Auto-readers with software version 4.2.7 or greater - Dynamic-air-removal (Pre-vacuum and SFPP): 132˚C (270˚F) 3 or 4 min. 135˚C (275˚F) 3 min. - Meets ISO and FDA performance requirements for biological indicators - Contains viable organisms that provide a direct measure of lethality - Puts your instrument turnaround speed into overdrive - Puts your instrument turnaround speed into overdrive for improved patient safety *When used with 3M™ Attest™ Auto-reader 490 or the Attest™ Auto-reader 490H with software version 4.2.7 or greater.

More Information

Q&A

Reviews

Returns